SI23 Solar Pump Inverter Manual
1
Chapter 1 Safety Requirement and Cautions
To ensure safety of your health, equipment and property, please read this chapter carefully before using the frequency inverter
and act in compliance with the instructions when installing,ebugging, running and overhauling the frequency inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the rules.
Note: some information is useful while operating and use frequency inverter.
1.2 Safety Requirements and Cautions
●Before Installation
Danger
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully read the manual about safety,
installation, operation and maintenance. The safe operation depends on the proper processes of choosing models,
carrying, installation, operation and maintenance.
Danger
1. Don’t use the damaged or incomplete frequency inverters; Otherwise, there is risk of injury.
●Installation
Danger
1. Please install the frequency inverter on metal or other nonflammable material, and keep it away from the combustible
material. Otherwise there is danger of fire;
2. No unauthorized modification to the frequency inverter; Otherwise there is danger of damaged.
3. Normal frequency inverter, which is not explosion-proof, can not be installed where with explosive gas or dust; Otherwise
there is danger of explosion.
Attention
1. When two frequency inverters are installed in the same control cabinet, pleas pay attention to the installing place to
guarantee the effective heat dissipation.
2. When carrying the frequency inverter, ease support its bottom.
●Wiring
Danger
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. AC power supply should not be connected with output ports U, V, W, otherwise there is a danger of damage to frequency
Question and Answer IconNeed help?

Do you have a question about the Veichi SI23-D1 series and is the answer not in the manual?

Veichi SI23-D1 series Specifications

General IconGeneral
Cooling MethodForced air cooling
Enclosure RatingIP20
Input Frequency50/60Hz
Control ModeV/F
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short circuit
CommunicationModbus RTU
Ambient Temperature-10°C to +40°C
Storage Temperature-20°C to +60°C
HumidityLess than 95% (non-condensing)
AltitudeBelow 1000m

Summary

Chapter 1 Safety Requirement and Cautions

1.1 Safety Definition

Defines "Danger" and "Caution" for safety warnings.

1.2 Safety Requirements and Cautions

Outlines safety requirements for installation, wiring, and operation.

Chapter 2 Installation and Wiring

2.1 Dimension of Inverter

Provides overall and installation dimensions for various inverter models.

Chapter 3 Keyboard layout and functions specification

Keyboard Appearance

Visual layout of the inverter's keyboard and display.

Key function

Explains the function of each key on the inverter's keyboard.

Chapter 4 Fault Diagnosis and Solution

Fault Information and Description in Detail

Lists fault codes, types, possible reasons, and troubleshooting steps.

Chapter 5 Parameters List

Basic parameters

Details of basic operational parameters for the inverter.

Chapter 6 Operation Guidance

6.1 Asynchronous Motor Pump Drive Operation Guidance

Guidance for wiring, parameter setting, and troubleshooting for asynchronous motors.

6.2 Synchronous Motor Pump Drive Operation Guidance

Guidance for wiring, parameter setting, and troubleshooting for synchronous motors.

6.3 PV Water Pump Features

Details on sleep, protection functions, and special features for PV water pumps.