EasyManua.ls Logo

Veichi SI23-T3-037G User Manual

Veichi SI23-T3-037G
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SI23 Solar Pump Inverter Manual
1
Chapter 1 Safety Requirement and Cautions
To ensure safety of your health, equipment and property, please read this chapter carefully before using the frequency inverter
and act in compliance with the instructions when installing,ebugging, running and overhauling the frequency inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the rules.
Note: some information is useful while operating and use frequency inverter.
1.2 Safety Requirements and Cautions
●Before Installation
Danger
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully read the manual about safety,
installation, operation and maintenance. The safe operation depends on the proper processes of choosing models,
carrying, installation, operation and maintenance.
Danger
1. Don’t use the damaged or incomplete frequency inverters; Otherwise, there is risk of injury.
●Installation
Danger
1. Please install the frequency inverter on metal or other nonflammable material, and keep it away from the combustible
material. Otherwise there is danger of fire;
2. No unauthorized modification to the frequency inverter; Otherwise there is danger of damaged.
3. Normal frequency inverter, which is not explosion-proof, can not be installed where with explosive gas or dust; Otherwise
there is danger of explosion.
Attention
1. When two frequency inverters are installed in the same control cabinet, pleas pay attention to the installing place to
guarantee the effective heat dissipation.
2. When carrying the frequency inverter, ease support its bottom.
●Wiring
Danger
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. AC power supply should not be connected with output ports U, V, W, otherwise there is a danger of damage to frequency
Question and Answer IconNeed help?

Do you have a question about the Veichi SI23-T3-037G and is the answer not in the manual?

Veichi SI23-T3-037G Specifications

General IconGeneral
BrandVeichi
ModelSI23-T3-037G
CategoryInverter
LanguageEnglish

Summary

Chapter 1 Safety Requirement and Cautions

1.1 Safety Definition

Defines "Danger" and "Caution" for safety context.

1.2 Safety Requirements and Cautions

Details safety rules for installation, wiring, and operation.

1.3 Cautions in Using

Provides important usage cautions for the frequency inverter.

1.4 Technical Specification

Lists detailed technical specifications of the solar pump inverter.

1.5 Cautions in Disposal

Advises on the proper disposal methods for the frequency inverter.

Chapter 2 Installation and Wiring

2.1 Dimension of Inverter

Provides overall and installation dimensions for inverter models.

2.2 Solar Pump Controller Wiring

Illustrates the standard connection diagram and wiring details.

Chapter 3 Keyboard layout and functions specification

3.1 Keyboard Appearance

Shows the layout and components of the inverter's keyboard.

3.2 Key Function

Explains the function of each key on the inverter's keyboard.

Chapter 4 Fault Diagnosis and Solution

4.1 Fault Information and Description in Detail

Lists fault codes, types, possible reasons, and troubleshooting steps.

Chapter 5 Parameters List

5.1 Basic Parameters

Details fundamental operational parameters and their settings.

5.2 Motor Parameters

Lists parameters specific to motor configuration and characteristics.

5.3 Protection and Malfunction Parameter Group

Outlines parameters for protection functions and malfunction handling.

5.4 Photovoltaic Pump Special Parameters

Covers parameters specific to photovoltaic pump operation.

Chapter 6 Operation Guidance

6.1 Asynchronous Motor Pump Drive Operation Guidance

Guides on wiring, parameter setting, and trial runs for asynchronous motors.

6.2 Synchronous Motor Pump Drive Operation Guidance

Guides on wiring, parameter setting, and trial runs for synchronous motors.

6.3 PV Water Pump Features

Explains special features for PV water pump operation like sleep and protection.

Related product manuals