Hosentopper VEIT 8741
VEIT 8741 Pants Finisher
The stop valve of the condensate drain is
closed.
The supply is dirty.
The steam nozzle is dirty.
The steam valve is defective.
The timer is defective.
Clean or replace it.
Clean or replace it.
Replace it.
Replace the PC-board.
The blowing air is insufficient.
The fluff filter is dirty.
The impeller is dirty.
The potentiometer is defective.
The phase control is defective
(Art.No.487315000 0).
Clean it.
Clean it.
Replace it.
Replace it.
The fan motor does not work.
The motor contactor is defective.
The waistband and hem tension is
insufficient.
The air pressure is too low.
Increase the pressure on the maintenance
unit.
The slide does not stop when moving
down.
The micro switch is defective.
Check the switch and the cable; replace, if
necessary.
The toothbelt makes noise
Friction between tooth belt and tooth
wheel
Spray Silicon Spray on the tooth belt
ERROR 1: UPPER
REED-CONT. MOTOR
No signal from upper reed sensor.
Magnet on the slide doesn’t reach the
upper reed.
Check the distance of upper between reed
sensor and the magnet. Adjust it if too far.
Replace defective reed. Replace defective
servo motor.
ERROR 2: BOTTOM
REED-CONT. MOTOR
No signal from bottom reed sensor.
Magnet on the slide doesn’t reach the
bottom reed.
Check the distance of bottom between
reed sensor and the magnet. Adjust it if
too far. Replace defective reed. Replace
defective servo motor.
Fail to save some values to memory
Restart the machine. If recurrence,
replace the Controller/Processor.
Fail to read some values from memory
Restart the machine. If recurrence,
replace the Controller/Processor.
No current flows to the motor.
Current detector cable short circuited to
the ground or not connected to the main
board
Check the motor and wiring. Replace
defective servo motor.
ERROR 8: SIGNAL
MOTOR-BRIDGE
No Signal of motor-bridge
Motor-bridge faulty
Error at the motor
Check motor-bridge.
Check the motor and wiring. Replace
defective servo motor.