Legal instructions, connection conditions of electricity and water
distribution organizations should be followed. No technical change is
allowed in electrical or water connection or in the device.
A breaker switch with full poles with minimum 3 mm contact distance
should be installed at the installation place.
Instant water heater is a device with Protection Class I and should be
connected with an earthed cable.
Avoid connections and materials those may create risk in the electricity
and water installation.
This device should be continuously connected to fixed installations.
Cable section should comply with the installed power.
Earthed water installations shall not be replaced with an earthing line.
Following the installation, electricity conducting components should be
protected against contact.
When the device is used for a certain period, pay attention that
connections may be very hot.
Do not use the device during or in probability of the frost. Water should be
completely liquid prior to use the device.
Demounted device should be kept away from the risk of frost and not
exposed to frost due to having water inside.