EN
Installation of Motor with built-in receiver + Remote Rontrol Topline - Beds with
RSM functionality (position monitoring)
Please connect the remote controls correctly for a proper use of the motor with built-in
receiver.
Note: in case of a double bed; PLEASE install both bed parts one by one, not
together!!
Connecting or linking of the remote control to the motor can be done in 2 different
ways:
• Automatic connecting mode:
o Plug the 220V power plug of the motor to the mains.
o After connection to the main power, the white LED lights of the motor
will light up and the receiver enters in an automatic connecting mode.
(FOR THIS REASON -in case of a double bed- PLEASE install
the bed parts one by one to avoid connection problems !!)
o You now have 60 seconds to connect the remote control.
o Press the remote buttons 1 & 2 (first row) TOGETHER.
o On the motor, the white LED flashes 2 x and goes out (the blue LED
flashes for another 60 seconds). The connection between remote
and receiver was successful.
o Note: sometimes the connection can take more than 10
seconds!!
o It’s necessary that a reference movement is now performed. Now
keep the connecting button A pressed. Both motors of the bed are
moving to their Zero Position. When the white LED light on the
motor flashes 2 x, the reference movement was successful.
o The adjustable bed is now ready to be used.
• Manual connecting mode:
o After the 60 seconds mentioned above the receiver leaves its
automatic connecting mode; the white LED lights go out and a
manual connecting mode has to be activated.
o On the motor, press 2 x the connecting button A until the white LED
lights will light up.
o You now enter the manual connecting mode.
o Press the remote buttons 1 & 2 (first row) TOGETHER.
o The white LED on the motor flashes 2 x and goes out. The
connection between remote and receiver was successful.
o Note: sometimes the connection can take more than 10
seconds!!
o It’s necessary that a reference movement is now performed. Now
keep the connecting button A pressed. Both motors of the bed are
moving to their Zero Position. When the white LED light on the motor
flashes 2 x, the reference movement was successful.