DCM268N
V. 02 – 20/08/2018 11 ©Velleman nv
The battery cover is located on the back of the device and is closed with
one screw. Remove the screw and open the battery compartment.
Remove the battery and insert a new 9V battery following the polarity as
indicated in the battery holder. Only use a new battery of the same type
and specifications.
Reinstall the cover and secure it with the screw.
Remove the battery when the device will not be used for a long time to
avoid leakage.
Do not recharge non-rechargeable batteries and do not throw in fire as
they may explode.
WARNING: handle batteries with care, observe warnings
on battery casing. Dispose of batteries in accordance with
local regulations. Keep batteries away from children.
11. Specifications
±(1.5% of rdg + 2 digits) / ±(0.8% of rdg + 2 digits)
for 0.4V range / ±(2.0% of rdg + 2 digits) for 600V
range
0.4/4/40/400/600V TRUE RMS
±(1.5% of rdg + 8 digits) / ±(1.0% of rdg + 10 digits)
for 0.4V range / ±(2.0% of rdg + 8 digits) for 600V
range
±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of
rdg + 8 digits) for 400A range / ±(3.0% of rdg + 8
digits) for 1000A range
±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of
rdg + 8 digits) for 400A range / ±(3.0% of rdg + 8
digits) for 1000A range