Pollution
degree 2
Only nonconductive pollution occurs. Occasionally, temporary
conductivity caused by condensation is to be expected.(home
and office environments fall under this category)
Pollution
degree 3
Conductive pollution occurs, or dry nonconductive pollution
occurs that becomes conductive due to condensation that is
to be expected.
(industrial environments and environments exposed to
outside air - but not in contact with precipitation)
Pollution
degree 4
The pollution generates persistent conductivity caused by
conductive dust or by rain or snow. (exposed outdoor
environments and environments where high humidity levels
or high concentrations of fine particles occur)
Warning: This device was designed in accordance with EN 61010-1
pollution degree 2. This implies that certain restrictions in use apply that
are related to pollution which can occur within the environment of use. Refer
to the table above.
This device is only suitable for measurements in Pollution
degree class 2 environments.
9. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II, CAT III and CAT IV
environments (see §7).
Use this meter only in a pollution degree 2 environment (see §8).
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
relative humidity: max. 80 % RH
altitude: max. 2000 m (6560 ft)
voltage ........................................................................... 600 V
fuse protection
F0.5 A/600 VDC, 5 x 20 mm (breaking capacity 10 kA)
F15 A/600 VDC, 5 x 20 mm (breaking capacity 10 kA)
power supply ................................................. 1 x 9 V 6F22 (incl.)
display ............................................................ LCD, 1999 counts
display dimensions ................................................... 62 x 36 mm
ranging mode ................................................................ manual
over-range .......................................................................... yes
continuity buzzer .................................................................. yes
diode test ............................................................................ yes
low-battery indication ........................................................... yes
data hold ............................................................................ yes