V. 01 28/11/2017 9 ©Velleman nv
backlight ............................................................................. yes
auto power-off ..................................................................... yes
dimensions ................................................... 190 x 100 x 40 mm
weight (with battery) ......................................................... 300 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe ........ CAT III 1000 V/ CAT IV 600 V, 15 A; L = 75 cm
IP rating ........................................................................... IP20
9.1 DC VOLTAGE
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
200 mV
0.1 mV
± (0.5 % rdg + 2 digits)
2 V
1 mV
20 V
10 mV
200 V
100 mV
600 V
1 V
± (0.8 % rdg + 2 digits)
Overload protection: 600 V DC or AC rms
Impedance: 10 MΩ
9.2 AC VOLTAGE
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
2 V
1 mV
± (0.8 % rdg + 3 digits)
20 V
10 mV
200 V
100 mV
600 V
1 V
± (1.2 % rdg + 3 digits)
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 600 V DC or AC rms
Impedance: 1 M on 2 V range, 10 M on other ranges