EasyManua.ls Logo

VENCO VHR 11 - User Manual

Default Icon
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION OPERATION &
MAINTENANCE INSTRUCTION
HEAT RECOVERY UNITS VHR AND VHR EC MODELS
VENCO Havalandırma ve Makina San.ve Tic. A.Ş.
2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE
Tel: +90 (236) 332 5070 Fax: +90 (236) 332 5030
www.venco.com.tr venco@venco.com.tr
2019.10

Other manuals for VENCO VHR 11

Questions and Answers

  • N
    nibarraJul 25, 2025
    What to do if my VENCO Heating System has low airflow?
    • J
      Jennifer RamirezJul 25, 2025
      If the VENCO Heating System experiences low airflow, several factors could be at play. First, pressure loss in the ducts might be higher than initially calculated, suggesting a need to review the duct design. Second, clogged or dirty filters can significantly impede airflow; cleaning or replacing the filter is advised. Lastly, excessive leakage on the pressure side of the system can diminish airflow, so inspect doors and duct connections for leaks.
  • S
    smithmeredithAug 5, 2025
    Why is there high airflow in my VENCO VHR 11 Heating System?
    • A
      Alexis HernandezAug 5, 2025
      If your VENCO Heating System exhibits high airflow, it could be due to a few reasons. Check the duct connections for excessive leakage on the suction side of the system. Also, the fan motors might be experiencing overcurrent, indicating the engine is overloaded, so measure the current drawn by the engine. Another potential cause is a low supply voltage; in this case, consider installing grills.
  • C
    carlchandlerAug 13, 2025
    How to troubleshoot no air flow in VENCO VHR 11 when the motor isn't working?
    • J
      jordanbradleyAug 13, 2025
      If there is no air flow and the motor isn't working in your VENCO Heating System, start by checking the power supply to ensure it's functioning correctly. If the power supply is okay, inspect the fan motor cables at the main controller board to ensure they are tightly connected, as thermal protection might be open. Also, verify the connection of the control panel by checking the socket behind the controller.

Summary

Technical Specifications for Heat Recovery Units

Unit Connections and Fittings

Duct Connections

Explains how to connect air ducts, ensuring proper airflow and preventing losses.

Drain Connections

Describes the correct method for connecting the drain pipe to prevent air suction and ensure proper drainage.

Electrical Connections

Emphasizes that electrical connections must be made according to EN 60204-1 by trained personnel.

Safety Requirements for Operation

Safety Labels on the Unit

Pre-Operation Checks and Controls

General Safety Recommendations

Unit Start-Up Procedures

Maintenance Schedule and Procedures

Control Functions Overview

Standard Electronic Controller (SEC) Functions

Explains the capabilities of the Standard Electronic Controller (SEC), including unit ON/OFF, fan speed, and mode selection.

Electronic Controller Button Functions

Details the functions of buttons on the electronic controller and explains how fans and heaters operate automatically.

Troubleshooting Common Issues

VENCO VHR 11 Specifications

General IconGeneral
BrandVENCO
ModelVHR 11
CategoryHeating System
LanguageEnglish

Related product manuals