DECO-TOUCH WALL CONTROL INSTALLATION AND OWNER GUIDE
THIS WALL CONTROL MAY BE USED WITH THE FOLLOWING VENTILATION UNITS:
VENMAR UNITS NEE UNITS
AVS SOLO AVS KUBIX HRV PLUS AND ERV • GOLD SERIES • HE*
AVS DUO • HE VIGÖR HRV PLUS • NOVO+
• COMPACT • NOVOFIT VIGÖR ERV • 60H*
• HRV AND ERV EKO 1.5 • HRV CONSTRUCTO 1.5V*, 1.5ES AND 2.0ES • HRV AND ERV 90H-V ECM • 100H
• ERV CONSTRUCTO 2.0ES • CONSTRUCTO 1.0* • 90H-V* • 200H
IT IS RECOMMENDED TO WEAR SAFETY GLASSES AND GLOVES WHILE PERFORMING THESE INSTRUCTIONS. ALWAYS DISCONNECT THE UNIT BEFORE MAKING ANY CONNECTIONS.
FAILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT.
WARNING
!
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT AND/OR THE WALL CONTROL:
• NEVER INSTALL MORE THAN ONE MAIN WALL CONTROL PER VENTILATION UNIT;
• KEEP CONTROL LOW VOLTAGE WIRING AT LEAST 1 FOOT (305 MM) AWAY FROM MOTORS, LIGHTING BALLAST, LIGHT DIMMING CIRCUIT AND POWER DISTRIBUTION
PANEL. DO NOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING;
• ENSURE THE WIRES ARE SECURELY CONNECTED.
CAUTION
UNPLUG THE VENTILATION UNIT FROM POWER SOURCE.
CUT A 2 7/8” X 1 3/8” HOLE IN A WALL, AT A
CONVENIENT LOCATION FOR THE WALL CONTROL.
ROUTE THE CABLE FROM THE UNIT TO THIS
HOLE.
NOTE: DIMENSIONS SHOWN ARE FOR AN INSTALLATION
WITHOUT WALL BOX.
TEMPORARILY PLACE THE SWITCH OVER THE HOLE
AND MARK BOTH MOUNTING SCREW HOLE POSITIONS.
REMOVE THE SWITCH, DRILL BOTH SCREW HOLES
(3/16” Ø) IN WALL AND INSERT WALL ANCHORS
(INCLUDED).
VC0116A
Ø 3/16”, typ.
STRIP THE END OF THE CABLE TO ACCESS
THE 4 WIRES. STRIP THE END OF EACH WIRE.
USING A SMALL BLADE SCREWDRIVER, CONNECT
EACH WIRE TO ITS CORRESPONDING TERMINAL, ON
THE BACK OF THE WALL CONTROL: YELLOW WIRE
TO “Y”, RED WIRE TO “R”, GREEN WIRE TO “G” AND
BLACK WIRE TO “B”.
MOUNT THE WALL CONTROL TO THE WALL. PLUG THE
VENTILATION UNIT AND TEST THE WALL CONTROL
OPERATION.
Y
B
G
R
VE0243
VC0115
*CONSTRUCTO 1.0 AND NEE 60H BUILT IN AUGUST 2008 AND LATER, NEE HE BUILT IN JULY 2006 AND LATER AND CONSTRUCTO 1.5V AND NEE 90H-V BUILT IN NOVEMBER
2012 AND LATER. THE DATE CODE ON THE UNIT IS PA RT OF ITS 13-DIGIT SERIAL NUMBER. FOR EXAMPLE, THE SERIAL NUMBER XXXX0708XXXXX, WHERE 07 IS THE YEAR AND 08 THE
MONTH (AUGUST), THE DATE CODE IS ALWAYS THE FIFTH, SIXTH, SEVENTH AND EIGHTH DIGITS.
WALL CONTROL INSTALLATION
WALL CONTROL USE
BACKLIGHT
IF THE BACKLIGHT IS NOT ILLUMINATED, THE FIRST BUTTON PRESSED (NO MATTER WHICH
BUTTON) SHALL TURN ON THE BACKLIGHT. THE BACKLIGHT REMAINS ILLUMINATED FOR
10 SECONDS AFTER THE LAST BUTTON PRESSED.
OPERATING MODES
OR
TO CHANGE THE OPERATION MODES OF THE VENTILATION UNIT, PRESS THE
UP OR DOWN ARROW BUTTON. OPERATING MODE LABEL WILL THEN SCROLL
UP OR DOWN ON LCD SCREEN.
OFF
PUT THE UIT ON STAND-BY MODE, SO IT WILL ONLY RESPOND TO OVERRIDE
WALL CONTROLS (IF PRESENT). ON LCD SCREEN, ONLY THE HOUSE IS
VISIBLE SHOWING THE CONTROL IS POWERED ON. THIS IS THE FACTORY
DEFAULT MODE.
RECIRC
AIR IS RECIRCULATED INSIDE THE HOUSE AT HIGH SPEED.
NOTE: THIS MODE IS NOT AVAILABLE WITH THE FOLLOWING UNITS:
HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES,
ERV CONSTRUCTO 2.0ES AND NEE 100H, 200H, 90H-V.
OPERATING MODES (CONTD)
20 MIN/H
THE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE
HOUR CYCLE AS FOLLOWS: OFF FOR 40 MIN. (OR RECIRCULATION*
ON HIGH SPEED FOR 40 MIN., SEE NEXT SECTION ON BACK PA GE ) AND THEN
EXCHANGE AIR DURING 20 MIN. ON LOW SPEED. REPEAT CYCLE AFTER THE
20 MIN. OF AIR EXCHANGE.
*EXCEPT FOR HRV CONSTRUCTO 1.5V, 1.5ES, 2.0ES,
ERV CONSTRUCTO 2.0ES AND NEE 100H, 200H AND 90H-V UNITS.
MIN
AIR IS EXCHANGED WITH THE OUTSIDE ON LOW SPEED.
MAX
AIR IS EXCHANGED WITH THE OUTSIDE ON HIGH SPEED.
09947 REV. 04