Do you have a question about the Venmar HEPA 3000 and is the answer not in the manual?
Model | HEPA 3000 |
---|---|
Filtration Technology | HEPA, Activated Carbon, Pre-filter |
HEPA Filter | Yes |
Activated Carbon Filter | Yes |
Pre-filter | Yes |
Coverage Area | Up to 3000 sq. ft. |
Voltage | 120V |
Filtration Stages | 3 |
Explains warning, caution, and note symbols used in the manual for safety and clarity.
Key safety warnings and cautions for operating and installing the units to prevent injury or damage.
Covers Stand Alone, Central Draw Point, and Return-to-Return installation methods for these models.
Details specific installation aspects for the HEPA 4000 model, including geographical considerations and attic installation.
Provides front and top view dimensions for HRV 2500 and HR 2.5 units, including mounting clearance.
Provides front and top view dimensions for HEPA 3000, HF 3.0, and HEPA 4000 units.
Details minimum clearance requirements for door operation and Tandem transition installation.
Instructions for checking the unit and its components for shipping damage before installation.
Lists necessary tools, materials, and specific installation kit numbers for different models.
Guidelines for choosing an appropriate location for the unit, considering temperature, access, and utilities.
Instructions on how to mount the 8" oval and 5" to 6" oval ports using provided screws.
Guides on using chains and springs to hang the unit in vertical or horizontal positions.
Advice on planning ductwork, minimizing bends, keeping lengths short, and avoiding specific areas.
Details on installing stale air exhaust and fresh air distribution ductwork for stand-alone systems.
Instructions for connecting fresh/filtered air ductwork to the forced air unit return duct.
Instructions for connecting fresh/filtered air and stale air ductwork for return-to-return systems.
Procedures for connecting insulated flexible ducts to Tandem transitions and unit oval ports.
Steps for assembling, locating, and connecting the dual exterior hood to the Tandem transition.
Step-by-step guide on how to connect the unit's drain fittings, tubing, and create a water trap.
Explains the 3-position main switch (OFF, NORMAL/REMOTE, BOOST) on the unit's front panel.
Identifies the included wall control models (C34 and CMR) for different unit series.
Details the functions of the C34/CMR control, including indicators and operating modes.
Detailed steps for biannual maintenance, including cleaning cores and replacing prefilters.
Instructions for annual maintenance, differing for HRV/HR and HEPA/HF models.
Procedure for resetting the filter maintenance indicator using the wall control.