5.12 Remove (1) hot tank screw from above.
5.13 Pull hot tank down
5.14 Disconnect (4) electrical connectors
from hot tank temperature sensors.
5.15 Hot tank can now be removed.
5.16 To replace the hot tank, reverse the
above procedure.
Removing/Replacing Hot Tank