8.4 There are (2) thermal sensors attached with
screws to the hot tank. The lower sensor auto-
matically turns the heating element on and off
to maintain the water at 180 ºF. The upper
sensor is the over temperature sensor. This
sensor activates if the temperature on the tank
goes over 212 ºF. If this sensor is activated due
to a overheat condition, it will cut the power to
the heating element. If this happens, it can be
reset by pressing the button at the center of
the sensor.
To check if either thermal sensor is good, use a
continuity tester (ohm meter) to check for
continuity across the thermal sensor. Make
sure the thermal sensor is at ambient temperature
for this test. If there is no continuity, replace
the sensor.
8.5 To change either sensor, disconnect (2)
electrical terminals from sensor.
8.6 Remove (2) screws holding sensor to tank.
8.7 Install new thermal sensor, replace screws,
reconnect electrical terminals to sensor.
8.8 Carefully relocate cooling grill to original
location and re-attach using rubber grommets
and screws.
Remove/Replace Thermal Sensor
cont.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertex PWC-1000 and is the answer not in the manual?

Vertex PWC-1000 Specifications

General IconGeneral
BrandVertex
ModelPWC-1000
CategoryWater Dispenser
LanguageEnglish

Related product manuals