Shutter Exhaust Fan User Manual
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only
represents an estimate of savings you might benefit from buying certain tools
with us compared to the major top brands and doses not necessarily mean to
cover all categories of tools offered by us. You are kindly reminded to verify
carefully when you are placing an order with us if you are actually saving half
in comparison with the top major brands.
Question and Answer IconNeed help?

Do you have a question about the VEVOR AMX-FAG10 and is the answer not in the manual?

Summary

Product Overview and Applications

Applications

Lists common uses such as public toilets, warehouses, factories, and shops.

Key Features and Components

Details main parts, motor, impeller, design, and overall functionality.

Safety Instructions and Warnings

General Safety Guidelines

Emphasizes reading all instructions, warnings, and diagrams carefully.

Operational and Environmental Restrictions

Covers prohibitions on high temperatures, steam, water spray, and cooking areas.

Installation and Usage Precautions

Details requirements for firm installation, height, and checks for safe operation.

Electrical Safety

Highlights the critical need for a grounding device to prevent electric shock.

Severe Weather Operation

Advises turning off power during severe weather like thunderstorms.

Technical Specifications and Dimensions

Overall and Installation Dimensions

Provides detailed measurements for various fan models.

Performance Specifications

Lists air volume, noise level, net weight, and applicable area.

Installation and Wiring

Installation Procedure

Step-by-step guide for mounting the fan, including hole size requirements.

Wiring Diagram and Connection

Illustrates the electrical connection for fan operation.

Troubleshooting and Maintenance

Malfunction Analysis

Identifies common issues like failure to start, noise, or vibration with potential causes.

Elimination Methods

Provides solutions for malfunctions, including professional checks and self-correction steps.

Manufacturer Information

Company Details

Provides the manufacturer's name, address, and country of origin.

Overview

This document describes the VEVOR Shutter Exhaust Fan, a product designed for indoor ventilation in various settings.

Function Description

The VEVOR Shutter Exhaust Fan (AMX-FAG series) is primarily used for indoor ventilation in a range of buildings. Its core function is to move air, facilitating air exchange and improving air quality in enclosed spaces. This makes it suitable for public toilets, warehouses, offices, factories, shops, and residential areas. The fan is designed to transfer air, but it's crucial to note that the air transferred should not be flammable, explosive, or corrosive.

Usage Features

The fan incorporates several features to ensure efficient and stable operation. It utilizes high-quality sheet metal materials for its main parts, contributing to its durability. The motor is designed for high efficiency, and the impeller is an axial type, optimized for high air volume. This combination results in a compact structure, large air volume, and stable operation.

Installation involves creating an appropriate-sized hole in the wall, as specified in the manual, and then fixing the fan with bolts. Electrical connection requires connecting the fan to a 120V/60Hz AC electricity supply, using a single-phase switch to control its start and stop.

During operation, several safety and functional considerations are highlighted. The fan should not be installed in high-temperature places where the ambient temperature exceeds 40°C. It is also forbidden to place the fan over cooking equipment or in areas with excessive lampblack. Proper ventilation setup is required. The installation height should be more than 2.3 meters. Furthermore, the fan should not be installed in locations with excessive steam or where it is easily sprayed with water. It must be installed firmly to prevent issues.

Before initial use, it's recommended to check that all components are securely connected. After installation, the blade should be moved by hand to ensure it runs well. Powering on the fan for 5 minutes allows for a check of smooth operation, absence of abnormal noise, and vibration. If any abnormalities are detected, the fan should be stopped and troubleshooted.

A grounding device is essential to prevent electric shock. Users should avoid forcibly opening or closing the shutter while the fan is running to prevent danger. In severe weather conditions, such as strong winds or thunderstorms, the power should be turned off to avoid potential hazards.

Maintenance Features

Maintenance of the VEVOR Shutter Exhaust Fan primarily involves troubleshooting common malfunctions and ensuring proper installation. The manual provides a guide for self-checking and identifying issues.

If the fan causes large noise and vibration while running, potential causes include:

  • Not being firmly installed: This can be resolved by reinstallation and fastening.
  • The device itself being loose: A professional should fix this.
  • The blade being covered with dust or component defects causing load changes: A professional should address this.
  • The device being blocked by foreign objects: Power off the fan and carefully remove the foreign objects. High-altitude operations for this task should be performed by professional personnel.
  • Incorrect voltage (too high or too low) affecting device speed: Professionals should check the voltage.

If the fan cannot be started or operated, potential causes and solutions include:

  • Power outage: Self-check for power source availability.
  • Circuit protection device tripping: Restart the power.
  • Voltage being too high or too low: Professionals should measure the voltage.
  • Fan blade blocked by foreign objects: Power off and remove foreign objects. High-altitude operations should be performed by professional personnel.
  • Short circuit: A professional should check this.
  • Motor burn: A professional should check this.
  • Capacitor burn: A professional should check this.

It is explicitly stated that users should not attempt to self-repair the fan, as improper operation and maintenance can lead to electric shock or fire. If issues persist after self-checking, users are advised to contact the dealer or a professional for repair.

The appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, provided they receive supervision or instruction on safe use and understand the associated hazards. Children should not play with the appliance, and cleaning and user maintenance should not be performed by children without supervision.

VEVOR AMX-FAG10 Specifications

General IconGeneral
TypeAxial Fan
ModelAMX-FAG10
Frequency60Hz
Blade MaterialAluminum
Noise Level65 dB