The self-protection of
the compressor
because of overload.
Find and solve the problem
The capacitor of the
compressor broke
Leakage of the
refrigerant
Find and repair the leak in the
pipe, then vacuum and recharge
the refrigerant
Change the electrical valve
Repair or change the fan motor
The capacitor of the fan
motor broke
Chang the capacitor of fan motor
There is some problem
with control panel.
Check and repair the refrigerating
system
Solve the problem of low voltage
There is some problem
with control panel.
Change the control panel.
The touch point of the
contact switch broke.
Remove the touch point or
change the contact switch.
The proportion of mix is
incorrect, and causes
the refrigeration
difference
Make up a proper proportion of
mix.
Pour the mix into the hopper
Limit switch broke or the
tie wire is unfastened.
Change the switch or fasten the
wire
The belt is unfasten or
skid around
Change or adjust the belt