- 5 -
indicator ( ) appears.
When in Relative mode or Data Hold mode or after zeroing the display
in DC current function, caution must be used because hazardous
voltage may be present.
Use the meter only as specified in this manual; otherwise the
protection provided by the meter may be impaired.
Adhere to local and national safety codes. Individual protective
equipment must be used to prevent shock and arc blast injury where
hazardous live conductors are exposed.
To avoid electric shock and personal injury, do not touch any naked
conductor with your hand or skin; and do not ground yourself while
using this meter.
Do not use the meter if the meter, a test lead or your hand is wet.
Remaining endangerment:
When an input terminal is connected to dangerous live potential, it is to
be noted that this potential can occur at all other terminals!
Do not use the VFD voltage measurement function or VFD current
measurement function to verify the presence of hazardous voltages or
currents. Voltages or currents greater than what is indicated may be
present.
CAT III - Measurement Category III is for measurements performed in
the building installation. Examples are measurements on distribution
boards, circuit breakers, wiring, including cables, bus-bars, junction
boxes,switches, socket-outlets in the fixed installation, and
equipment for industrial use and some other equipment, for example,
stationary motors with permanent connection to the fixed installation.
Do not use the meter for measurements within Measurement Category
IV.