- 10 -
blades.The blades are balanced as sets.
Check the blade bolts and the hub but for tightness.
Check nosecone for cracks and proper fit.
Wash off any built-up dirt or debris from the blades.
Check all electrical connections to make sure they are tight and free
from corrosion.
As with all charging systems,check your battery water levels and add
distilled water in accordance with manufacture’s recommendation.
We suggest replacing the blades and bearing every five years for
optimal performance.
CAUTION: Never approach the turbine during operation.
5.TROUBLE CLEARING
The power generation system design is extremely demanding, under
normal installation and use do not usually fail. Under special circumstances,
please refer to the following table:
Fan
vibration
Failure
Causes
1. Rope loose
2. Fixed blade bolts loose
3. Wind turbine blades by external defect
4. Imbalance caused by blade
attachments
Exclusion
Method
1. Adjust the tension rope
2. Tighten loose part
3. Replace blades
4. Clear attachments
Abnormal
murmur
Failure
Causes
1. Loose fasteners
2. Alternator bearing damage
3. Wind wheel and other parts of the
friction