Condensation on Refrigerator Surface
When the ambient air humidity exceeds 75%, slight condensation will occur on the
box surface, which is normal.
Failures and Solutions
E1: Low Input Voltage
Failure 1: Insert the refrigerator power cord into the cigarette lighter before the car
starts. Solution 1: Wait a while to connect the car after it starts.
Failure 2: The input voltage of the adapter is too low.
Solution 2: Adjust the battery protection level to middle-voltage or low-voltage. If it
doesn't work, please replace a new adapter.
E2: Fan Fault
Please replace a new fan when you identify there is a fan malfunction.
E3: Input Voltage Fault Due to Compressor Frequently Start
When the refrigerator is used in the car, and E3 appears, Please shut it down for 5
minutes and restart it.
If it doesn't work, that can be identified to be El fault; please solve it according to
the solution of El.
When the refrigerator is connecting with the adapter and E3 appearing
Please adjust the battery protection level to the middle or low level.
If it doesn't work, please replace a new adapter.
E4: Low Rotational Speed of Compressor
Please adjust the input voltage and repower it.
E5: Overheating of Controller Chip