Vent system must terminate to the outside (roof or side wall).
DO NOT terminate the vent system in an attic or other enclosed area.
DO NOT use 4” or 5” laundry-type wall caps. Use a 6” or larger Wall/Roof Cap.
Use metal/aluminum vent only. We recommend using Rigid instead of Flex duct.
It is recommended that the range hood be vented with a 6” or bigger round metal/aluminum
vent work.
The size of the vent should be uniform.
Use no more than two 90° elbows.
Make sure there is a minimum of 24” (61 cm) of straight vent between the elbows if more
than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of elbows should be kept to a minimum to provide
Use aluminum foil tape to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the cap.
Use 45 degree elbows instead of 90 degree elbows when possible.
IMPORTANT:
A minimum of a 6” round duct (standard for this range hood) must be used to maintain
connecting to provided duct.
Please use Duct Run Calculation below to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns in the duct run. If a
long duct run is required, increase the duct size from 6” to 8”. If a reducer is used, install a
If turns or transitions are required: Install as far away from opening and as far apart,
between 2, as possible.
Minimum Duct Size:
Round - 6” minimum
| SUNSET6
VENTING REQUIREMENTS