Do you have a question about the Victron energy BMV-700 and is the answer not in the manual?
Display Type | LCD |
---|---|
Communication | VE.Direct |
Battery Capacity Range | 1 - 999 Ah |
Accuracy Voltage Measurement | 0.5% |
Overall Accuracy | 1.0% |
Operating Temperature Range | -20 to +50 °C |
Shunt | Not included |
Shunt Voltage Drop | 50 mV at 500 A |
Essential instructions for safe installation, operation, and maintenance of the battery monitor.
Crucial warnings regarding handling lead-acid batteries and potential hazards like explosive gases.
Guidelines for storing the product in a dry environment and within specific temperature ranges.
Explains the BMV-700's function, measurements, and capabilities for battery monitoring.
Details the benefits of battery monitoring for extending battery life and optimizing performance.
Information on the BMV-700's shunt capacity and compatibility with larger shunts.
Introduces the VictronConnect app for configuration and monitoring via Bluetooth or USB.
Lists optional accessories required for specific setups, such as GX devices and interface cables.
Lists all components included in the BMV-700 package for installation.
Instructions and considerations for securely mounting the BMV-700 shunt in a dry location.
Describes various methods for mounting the BMV-700 head unit, including panel and wall mounting.
Identifies and explains the purpose of each terminal and connector on the BMV-700.
Step-by-step guide for making the fundamental electrical connections for the battery monitor.
Explains the function and application of the BMV-700's programmable relay for alarms or generator control.
Guidance on using shunts other than the supplied 500A shunt for higher current systems.
Details how to connect the BMV-700 to a GX device for system monitoring and remote access.
Guides through the initial setup process for the battery monitor upon first power-up or reset.
Explains how the monitor automatically detects and sets the nominal battery voltage.
Overview of methods for changing settings via the head unit or VictronConnect app.
Instructions on navigating and modifying settings using the BMV-700's physical buttons.
Details on using the VictronConnect app for easier configuration and firmware updates.
Recommends and guides on updating the BMV-700 firmware using the VictronConnect app.
Covers critical settings like battery capacity, charged voltage, and state of charge synchronization.
How to configure the battery capacity in Ah for accurate monitoring.
Setting the voltage threshold for recognizing a fully charged battery.
Configuring the 'start synchronized' option for initial state of charge reporting.
Specific configuration adjustments required for lithium-ion battery chemistries.
Explains the fundamental principles behind the battery monitor's calculations and measurements.
Describes the various parameters displayed on the head unit and in the VictronConnect app.
Details how to navigate and use the BMV-700's menus and buttons for operation.
Information on using the VictronConnect app for data logging and viewing historical trends.
How to access and interpret historical data stored by the battery monitor.
Guide to viewing historical data within the "History" tab of the VictronConnect app.
Instructions for accessing historical data directly through the BMV-700's head unit menus.
Explanation of the different historical data points recorded, such as discharge and charge information.
How the battery monitor generates and indicates alarms for low SOC, voltage, and high voltage.
Explains the importance of synchronization for accurate state of charge readings.
Details the automatic process of synchronizing the state of charge to 100% after a full charge.
Methods for manually synchronizing the battery monitor's state of charge.
How to connect the BMV-700 to a computer or device using the VictronConnect app via USB.
Instructions for connecting the BMV-700 to a GX device for monitoring and remote access.
Details on integrating the BMV-700 into a VE.Smart network via Bluetooth.
Advanced topic on using the VE.Direct port for custom programming and data integration.
Overview of accessing and modifying settings via the head unit or VictronConnect app.
Step-by-step guide for navigating and changing settings using the BMV-700 buttons.
Instructions for accessing and modifying settings through the VictronConnect mobile application.
Features for managing settings files within the VictronConnect app.
Detailed explanation of all battery-specific settings for fine-tuning monitor performance.
Setting the battery's capacity in Amp-hours for accurate monitoring.
Setting the voltage threshold for recognizing a fully charged battery.
Setting the minimum state of charge for 'time remaining' calculations and alarms.
Defining the charge current threshold below which charging is considered complete.
Setting the duration for which charged voltage and tail current must be met for synchronization.
Adjusting the Peukert exponent for accurate capacity calculation at different discharge rates.
Setting the efficiency factor to compensate for capacity losses during charging.
Defining a current threshold to filter out small currents that can affect readings.
Configuring the averaging period for the 'time-to-go' calculation.
Setting to assume 100% charge on startup.
Manually setting the current state of charge if needed, after initial synchronization.
Manual option to synchronize the state of charge to 100%.
Calibrating the monitor to ensure accurate current readings by removing offsets.
Configuration options for the programmable relay's function and behavior.
Selecting the operational mode for the programmable relay (e.g., default, charger, remote).
Option to invert the normal energized/de-energized states of the relay.
Read-only display of the current state (open or closed) of the relay.
Setting a minimum duration for the relay to remain closed after activation.
Setting a delay before the relay opens after the de-energize condition is met.
Configuring the relay to activate based on a low state of charge threshold.
Configuring the relay to activate based on a low battery voltage threshold.
Configuring the relay to activate based on a high battery voltage threshold.
Configuring alarm triggers for low SOC, low voltage, and high voltage conditions.
Enabling or disabling the audible buzzer for alarm events.
Setting activation and deactivation thresholds for low state of charge alarms.
Setting activation and deactivation thresholds for low battery voltage alarms.
Setting activation and deactivation thresholds for high battery voltage alarms.
Customizing the display appearance and information shown on the head unit.
Adjusting the brightness level of the display backlight.
Option to keep the backlight continuously active without auto-off.
Adjusting the speed at which information scrolls on the display.
Enabling or disabling the display of main battery voltage in the monitoring menu.
Enabling or disabling the display of current in the monitoring menu.
Enabling or disabling the display of power measurement in the monitoring menu.
Enabling or disabling the display of consumed Amp-hours in the monitoring menu.
Enabling or disabling the display of state of charge in the monitoring menu.
Enabling or disabling the display of estimated time remaining.
Various system settings including software version, defaults, history, and lock setup.
Displays the current firmware version of the battery monitor.
Resets all settings back to their original factory default values.
Deletes all historical data recorded by the battery monitor.
Prevents changes to settings via the head unit, locking them as read-only.
Setting the rated current for non-standard shunts used with the monitor.
Setting the rated voltage for non-standard shunts used with the monitor.
Setting to assume 100% charge on startup (also listed under Battery settings).
Other settings available within the VictronConnect app, not in the main settings menu.
Option to reset historical data from within the VictronConnect app.
Procedure to reset the Bluetooth connection PIN code to its default.
Location to find the unique serial number of the battery monitor.
Allows renaming the battery monitor for easier identification.
Information about the battery monitor's firmware and update capabilities.
Resets all settings to factory defaults, separate from clearing history.
Troubleshooting steps for issues like the unit being dead or settings not changing.
Checks for power issues when the BMV-700 head unit does not turn on.
Solutions for when settings cannot be modified via the VictronConnect app.
Steps to resolve problems connecting via Bluetooth or other methods.
Troubleshooting tips for Bluetooth connection failures with the battery monitor.
Procedure for resetting a lost or forgotten Bluetooth PIN code.
Diagnosing and resolving issues related to inaccurate displayed values.
Correcting reversed current readings by swapping power cables.
Addressing issues where current is not fully measured due to incorrect wiring.
Resolving false current readings through calibration or threshold settings.
Identifying causes for inaccurate SOC readings, including settings and synchronization issues.
Solutions for when the state of charge displays as missing or un-synchronized.
Troubleshooting why the SOC fails to reach 100% after charging.
Diagnosing why the SOC is permanently displayed as 100%.
Addressing issues with SOC changing too slowly or too quickly during charging.
Troubleshooting inaccurate battery voltage readings, checking connections and wiring.
Resolving problems where automatic synchronization fails or occurs too early.
Comprehensive specifications and performance data for the BMV-700 battery monitor.
Detailed physical dimensions and mounting information for the BMV-700 head unit.
Physical dimensions and mounting details for the BMV-700 shunt.