EasyManua.ls Logo

Viesa AGRO - Page 43

Viesa AGRO
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOLUTIONS
The equipment works well, but
the fuse burns out continuously.
1- Short-circuit in the blower or
in its connections.
2- Short-circuit in the water
pump or its connections.
3- Damaged power wire.
1- Replace the blower or repair.
2- Replace the water pump or
repair.
3- Locate, repair and seal
correctly.
Water pump operation not
showing on display.
(blower works at one speed only)
1- Inverted electrical connections
2- Faulty power and control 2- Replace the command and
control module.
Power module burns out. 1- Seized biturbo blower. 1- Replace biturbo blower motor.
PROBLEM
POSSIBLE CAUSES
SOLUTIONS
Pump cycles are not right ones.
Blower at its maximum speed
cannot be turned off.
1- Faulty power module. 1- Replace the power module.
Check the free spinning of the
blower.
1- Water Cycle Switch with
wrong setting.
1- Reset Water Cycle Switch
according to water column height.
module.
to battery.
1- Connect red wire to +
black to -
Blower works, display shows
normal operation but the
pump doesn’t work.
1- False contact and/or
disconnection of the ribbon cable.
(control and command module)
2- False contact and/or
disconnection of the water pump.
3- Faulty control and command
module.
4- Faulty water pump.
1- Repair and/or connect.
2-
Repair and/or connect.
Tin terminals of the water pump.
3- Replace the control and
command module.
4- Replace the water pump.
The speeds do not match the
display indications or they do not
change.
1- Faulty blower.
3- Faulty power module.
1- Replace the motor of the
blower.
3- Replace the command and
control module.
2- Humidity or water in the 2- Clean and seal. Check condition
of evaporator.
power module's terminals.