7Commissioning
Changing Existing Time Phases
Press the following keys:
1. Press INFO
2. Press MODE
3. Select "SETTINGS" with <--/-->
4. OK to conrm
5. Select "PROGRAMMING" with <--/-->
6. OK to conrm
7. Select the required program with <--/-->
8. OK to conrm
9. EDIT, "CHANGE" appears
10. OK to conrm, to change the switching time.
Days flash
<--/--> for "CLEAR" and OK, to delete the
switching time
11. +/- for the required group of days or single
day
12. OK to conrm
13. +/- for the required temperature level (e.g.
Comfort 1)
14. OK to conrm
15. +/- for hour (start time)
16. OK to conrm
17. +/- for minute (start time)
18. OK to conrm
19. OK to change further switching times
ESC to exit programming
Creating New Time Phases
Press the following keys:
1. Press INFO
2. Press MODE
3. Select "SETTINGS" with <--/-->
4. OK to conrm
5. Select "PROGRAMMING" with <--/-->
6. OK to conrm
7. Select the required program with <--/-->
8. OK to conrm
9. NEW
Days flash
10. +/- for the required group of days or single
day
11. OK to conrm
12. +/- for the required temperature level (e.g.
Comfort 1)
14. OK to conrm
15. +/- for hour (start time)
16. OK to conrm
17. +/- for minute (start time)
18. OK to conrm
19. OK to change further switching times
ESC to exit programming
Calling up Switching Times
Press the following keys:
1. Press INFO
2. Press MODE
3. Select "SETTINGS" with <--/-->
4. OK to conrm
5. Select "PROGRAMMING" with <--/-->
6. OK to conrm
7. Select the required program with <--/-->
8. OK to conrm
9. Press NEXT to call up the set switching
times one after another
10. ESC to exit programming
Deleting the Time Program
Press the following keys:
1. Press INFO
2. Press MODE
3. Select "SETTINGS" with <--/-->
4. OK to conrm
5. Select "PROGRAMMING" with <--/-->
6. OK to conrm
7. Select the required program with <--/-->
"CLEAR P..."
8. OK to conrm
9. Select "CLEAR PROG" with <--/-->
10. OK to conrm
Conrm appears
11. OK to conrm
12. ESC to exit programming

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann OpenTherm VITOTROL 100 OT and is the answer not in the manual?

Viessmann OpenTherm VITOTROL 100 OT Specifications

General IconGeneral
BrandViessmann
ModelOpenTherm VITOTROL 100 OT
CategoryTemperature Controller
LanguageEnglish

Related product manuals