Required parameter settings
ID: 4605509_1304_01
Parameter Value Function
7000 10 With heating circuit A1/HC1, M2/HC2, M3/HC3, DHW cylinder
7A00 3 Solar control module, type SM1
C002 2 Variable speed solar circuit pump with PWM activation
7100 2 Natural cooling NC-Box with mixer
7101 3 Cooling via heating circuit M3/HC3
7103 180 Min. flow temperature, cooling
7104 50 Influence room temperature hook-up cooling circuit
7105 1 Room temperature-dependent natural cooling
7111 4 Cooling curve slope
7D00 1 Enable Vitovent 300-F
7D02 1 Enable hydraulic reheater coil
3003 1 Vitotrol 300B remote control activated for heating circuit M3/HC3
Vitocal 222-G/242-G/333-G/333-G NC/343-G