Required parameter settings
ID: 4605507_1304_02
Vitotronic 200, type WO1C
Parameter Value Function
2003 1 Enable remote control for heating circuit A1/HC1
3003 1 Enable remote control for heating circuit M2/HC2
7000 6 With heating circuit A1/HC1, M2/HC2, DHW cylinder, heating water buffer cylinder
7008 1 Enable swimming pool heating
7010 1 External extension
701B 1 Common system flow temperature sensor is activated
7100 3 Enable active cooling function
7101 2 Cooling via heating circuit M2/HC2
7103 180 Min. flow temperature, cooling
7B00 1 Enable external heat source for central heating
7B0D 1 Enable external heat source for DHW heating
6014 1 Immersion heater or external heat source is enabled for DHW reheating
Vitotronic 200, type KO1B, KO2B, KW6B
Group Code Function
"General" 3A : 3 Function input DE1 at EA1 extension: External blocking
"General" 3b : 2 Function input DE2 at EA1 extension: External demand
"General" 9b : 70 Set value for external demand (delivered condition)
Vitocal 200-A
(cont.)
System examples