12
Vitotrol 100, type OT1
Type of installation: Wall mounting
On an inner wall in the main living room, approx.
1.5 m from the floor
The installation location must be dry and frost-free.
Ensure ambient temperatures between 0 and
+40 °C.
Not in the immediate vicinity of doors and windows
Not above radiators
Not in shelving, niches etc.
Not close to sources of heat (direct sunlight, fire-
place, television etc.)
Ranges
The range of Wi-Fi connections can be reduced by
walls, ceilings and furniture. The strength of the Wi-Fi
signal gets reduced and reception can be disturbed.
Reduction of the range:
Wi-Fi signals get attenuated on the way from the
transmitter to the receiver, for example, through the
air and when penetrating walls.
Wi-Fi signals are reflected by metallic parts,
for example, reinforcement in walls, metal foils of
heat insulation and metallised thermo-glass for heat
insulation.
Wi-Fi signals are cut off by supply blocks and lift
shafts.
Wi-Fi signals are disturbed by devices that also
work with high-frequency signals. Keep a distance of
at least 2 m to the following devices:
Computers
Audio and video systems
Radio signals
Electronic transformers
Ballasts
Note
We recommend keeping the distance between the
Vitoconnect and the Wi-Fi router as small as possible
to ensure a good Wi-Fi connection.
Preparing for installation
Installation site (cont.)
5813605
Installation