EasyManua.ls Logo

Viessmann VITOSOL 200-T SP2A User Manual

Viessmann VITOSOL 200-T SP2A
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Data Manual
5782 590 - 02 01/2015
Model Nos. and pricing: see Price List
VITOSOL 200-T Type SP2A
Vacuum tube collector
For the heating of DHW, supplement heating systems
and swimming pool water via heat exchangers as well
as for the generation of process heat.
For installation on pitched and flat roofs, as well as for
freestanding installations and on walls.
VITOSOL
r
200-T SP2A
Product may not be exactly as shown
Vacuum tube collector based on the heat pipe principle
For the utilisation of solar energy
Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOSOL 200-T SP2A and is the answer not in the manual?

Viessmann VITOSOL 200-T SP2A Specifications

General IconGeneral
TypeEvacuated tube collector
Absorber Area2.1 m²
Number of Tubes12
Maximum Operating Pressure10 bar
Aperture area2.1 m²
Absorber materialCopper
Maximum operating temperature120°C
Connection size22 mm
Length of Tubes1.8 m
Width1.03 m

Summary

Product Information

Product Description

Detailed description of the Vitosol 200-T SP2A vacuum tube collector's features and capabilities.

Benefits

Key advantages of the Vitosol 200-T SP2A vacuum tube collector, highlighting efficiency and installation flexibility.

Delivered Condition

Information on how the Vitosol 200-T SP2A vacuum tube collector is packed and delivered.

Specification

Technical Specifications

Detailed technical data and dimensions for Vitosol 200-T models including areas, dimensions, and performance metrics.

Tested Quality

Details on the quality certifications and testing standards met by the Vitosol 200-T collectors.

Design Information: Installation on Sloped Roofs

Installation with Roof Brackets

Details on the roof bracket system for Vitosol 200-T collector installation, including components and forces.

Design Information: Installation on Flat Roofs

Collector Supports

Information on collector supports for flat roof installations, including fixed and adjustable angle options.

Ballast and Load Calculation

Guidance on substructure ballast and load calculations for flat roof installations as per DIN standards.

Collector Row Clearance

Methodology for calculating collector row clearance (z) to prevent shading in flat roof installations.

Design Information: Installation on Walls

Horizontal Installation on Walls

Details on horizontal installation of Vitosol 200-T collectors on walls, including balcony mounting.

Design Information: Installation Examples

Array Connection Types

Examples of connecting Vitosol 200-T collectors in single rows, multiple rows, and arrays for optimal performance.

Design Information: Pressure Drop

Pressure Drop Chart

Chart illustrating the pressure drop in Vitosol 200-T collectors relative to flow rate for different models.

Design Information: Flow Rate

Individual Collector Flow Rates

Required flow rates for individual Vitosol 200-T collector models in high, medium, and low-flow modes.

Recommended Collector Array Flow Rates

Recommended flow rates for Vitosol 200-T collector arrays of various sizes and configurations.

Related product manuals