Change the address code if the wireless
connection between the Vitotrol 100 and
the wireless receiver fails.
1.
Press and hold B on the wireless
receiver (see diagram on page 12) for
approx. 10 s until LED
r
flashes.
2. Carry out the following settings on
the Vitotrol 100:
Open the flap of the Vitotrol 100.
3. Press twice.
4. Select "Settings" with / .
5. Confirm with OK.
6. Select "Service" with / .
7. Press OK three times to confirm.
8. Select "Address code" with / .
9. Confirm with OK.
After approx. 30 s the display shows
"Transmitting".
The transmission takes approx.
30 s.
LED flashes briefly during trans-
mission.
The LED extinguish when the address
code has been recognised. If not, repeat
the process.
Service settings
Changing the address code
5461 060 GB