Vitodens 200, Programming unit with Vitotronic 200, H01 on-board control.
VITOTRONIC 200®
Quick Start Programming Guide
Product may not appear exactly as shown.
for use with the Operating, Installation and Service Instructions
B C
D
E
F
G
H
IJ
K
L
M
N
O
PQ
A
A
Time program for central heating
B
Time program for DHW heating
C
Holiday program
D
Information
E
Standby mode
F
DHW only
G
Central Heating and DHW
H
Normal room temperature adjust
I
Energy saving mode ON/OFF
J
Party mode ON/OFF
K
Factory default factory setting
L
Confirmation button
M
Adjustment buttons
N
DHW temperature
O
Emissions test function (heating contractors only)
P
Reduced room temperature
Q
Time/Date
Vitodens 200, Vitotronic 200, H01 Control Lay-out
1
1
NOTE: The control will display the boiler temperature when not in the programming or fault mode.
1
2
These symbols are not displayed continuously, but appear according to system type and operating status.
Display Symbols
Risk of frost
Central heating with normal room temperature
Central heating with reduced room temperature
Frost protection heating circuit pump ON
Normal heating circuit pump ON
Reduced heating circuit pump ON
Mixing valve open
Mixing valve closed
Manual override operation
Automatic operation
DHW heating enabled
DHW pump ON, DHW heating enabled
DHW heating via solar heating system
Burner ON
Time adjustment display
Emissions test ON
Fault indicator
1
Heating circuit number
Scanning hours run, scanning number of
burner starts and consumption
NOTE: To adjust the display contrast, press and hold
and use the buttons for the desired setting.
1
10
1
Press for approximately 2 seconds.
2
Select the acknowledged fault code message
with the buttons.
3
Correct each fault as per the troubleshooting
section of the Installation and Service Instructions.
4
After each fault is removed, press the reset to
acknowledge.
Troubleshooting
1
Press and simultaneously for approximately
2 seconds.
2
Select the saved fault code message with the
buttons.
3
All fault codes can be deleted by pressing .
Delete? Yes, will appear, press for yes or no.
4
To finish the fault scan, press .
Calling up acknowledged fault messages
Retrieving fault codes from the fault history
NOTE: For additional information on troubleshooting and operating status, refer to the Operating,
Installation and Service Instructions supplied with the system.
1
11
Additional Functions
Heating Time Program
Domestic Hot Water Time Program
DHW Recirculation Pump Time Program
Holiday Program
Heating Curve Slope (located in Coding 2)
Heating Curve Shift (located in Coding 2)
Standby Mode
Domestic Hot Water Only
Party Mode
Energy Saving Mode
!
Participant Check (only on LON devices)
!
Boiler Sequence (on Cascade Control)
!
Cascade Control
!
Starting/Stopping DHW Heating Only
!
Starting/Shutting Down Heating System Only
!
Starting/Stopping DHW and Heating System
!
Remote Controls
NOTE: For information to access the additional
functions, refer to the Operating, Installation and
Service Instructions supplied with the system.
1
9
Coding Level 1 and 2
Calling up coding level 1 (Basic programming)
1
Press and simultaneously for approximately
2 seconds.
2
Select the required coding address with the
buttons, the address will flash, confirm
with , the value will flash.
3
To change the value, press the buttons,
once complete confirm with .
4
Call up additional coding addresses with the
buttons.
5
To exit coding level 1, press and
simultaneously for approximately 1 second.
Calling up coding level 2 (Detailed programming)
1
Press and simultaneously for approximately
2 seconds and confirm with
.
2
Select the required coding address with the
buttons, the address will flash, confirm
with , the value will flash.
3
To change the value, press the buttons,
once complete confirm with .
4
Call up additional coding addresses with the
buttons.
5
To exit coding level 2, press and
simultaneously for approximately 1 second.
1
Press and simultaneously for approximately
2 seconds .
2
Press factory default button and confirm ‘Base
setting? Yes’ with .
Resetting the codes to the factory setting
NOTE: Coding level 2 contains all of coding level 1
programming information.
NOTE: For coding level 1 and coding level 2 listings,
refer to the Installation and Service
Instructions supplied with the system.
5728 014 v1.0
Technical information subject to change without notice.

Other manuals for Viessmann VITOTRONIC 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOTRONIC 200 and is the answer not in the manual?

Viessmann VITOTRONIC 200 Specifications

General IconGeneral
ModelVITOTRONIC 200
CategoryControl Unit
ManufacturerViessmann
DisplayLCD
ConnectivityWired
CompatibilityViessmann heating systems
Operating Voltage230 V AC
ApplicationHeating systems
Operating modesAutomatic, Holiday
Ambient temperature0°C to +45°C
Temperature sensorIntegrated

Related product manuals