116
NOTE:
1. Behavior at Lock Modes
Lock Mode Behavior
Buon Lock
1. Lock all buons on the front panel and RCU, except for “Power”
2. All the SET funcons should be workable via RS-232, even the ones
with according hot key in RCU like Mute,…etc.
MENU Lock
1. Lock “MENU’ key of front panel and RCU
2. The Factory and Hospitality modes should not be blocked for the
model using MENU-combined key to enter these two modes.
Alternave approach will be indicated separately if any limitaon by
model.
POWER Lock
1. Lock “POWER” key on the front and RCU.
2. The SET_POWER on/o should be workable via RS-232, but does not
mean the POWER lock will be released under this case.
3. Can not be unlocked by reset in OSD seng
4. Will auto AC power-on in power-lock
5. Under power-lock, the set will not enter power saving when no PC
signal and neither not turn o when no other video signals aer 15
minutes.
Remote control
disable
Lock the RCU keys, but keep the front panel buons workable.
2. Wake-on-LAN by MAC address as alternave for SET Power on
(Length=126 Bytes)
6 Bytes 6 Bytes (#1) 6 Bytes (#2) ... 6 Bytes (#16) 24 Bytes
0xFF FF ... FF MAC address MAC address … MAC address 0x00 00 … 00