5-1.1 Product
17” LCD Monitor
5-1.2 Test Equipment
Color Video Signal & Pattern (or PC with SXGA resolution)
5-1.3 Test Condition
Before function test and alignment, each LCD Monitor should be run-in and warmed up for at least
30 minutes with the following conditions:
(a) In room temperature,
(b) With full-white screen, RGB, and Black
(c) With cycled display modes,
640*480 (H=43.27 kHz, V=85Hz)
800*600 (H=53.7 kHz, V=85Hz)
1024*768 (H=68.67 kHz, V=85Hz)
1280*1024(H=80.0KHz, V=75Hz)
5-1.4 Test Display Modes & Pattern
5-1.4.1 Compatible Modes
Analog Digital
Item