629
Child lock: (DFUD142only)
Activation of setting menu:
1. Turn off the main switch
2. Wait for at least 5 seconds
3. Keep the Temperature and Drying
selection buttons depressed (S4 &
S6)
4. Turn on the main switch
5. Release the Temperature and
Drying selection buttons (S4 &
S6)
6. Select the status with the program
button (S1).
L1 extinguished, key extinguished:
Child lock deactivated.
L1 lit, key lit: Child lock activated.
7. Confirm your selection by
pressing Start (S2)
The program returns to the main menu.
To unlock the child lock temporarily, the
Temperature (S4) and Drying selection
(S6) buttons must be press
simultaneously. The machine can now
be opened normally for three minutes.
Total reset:
To reset the machine to its basic settings.
1. Turn off the main switch
2. Wait for at least 5 seconds
3. keep the Program button depressed
(S1)
4. Turn on the main switch
5. Release the Program button (S 1)
The machine now resets various settings,
although not the water hardness and
intake volume, and senses the presence
of the turbidity and pressure sensors and
the spray arm divider. The machine then
reverts automatically to the main menu.
SERVICE MENU:
1. Turn off main switch
2. Wait for at least 5 seconds
3. keep the Program and Start buttons
depressed (S1 & S2)
4. Turn on the main switch
5. Release the Program and Start
buttons (S1 & S2)
The most recent fault is indicated as L1-
L6. Press the Program button and index
through the following components.
1. Inlet valve
2. Detergent and detergent dispenser
3. Circulation pump
4. Heating element and circulation
pump (Max 165
º
F)
5. Fan
6. Drain pump
Keep the Program button depressed for
three seconds to adjust the water intake
Press the Program button and index
through the following:
L1-L6 extinguished; Normal water
intake volume.
L1 lit; Water intake volume is reduced
by 10%.
L2 lit; Water intake volume is reduced
by 5%.
L3 lit: Time-controlled water intake
L4 lit: Water intake volume is increased
by 5%.
L5 lit: Water intake volume is increased
by 10%.
L6 lit: Water intake volume is increased
by 15%.
Confirm your choice by pressing Start
(S2). The program returns to the main
menu.