The K-2000-DVA Digital Announcer is
designed to be fully compatible with the
Viking models RC-2A and RC-3 remote
DTMF controllers. No conflicts between the
devices will occur, provided that both units
are accessed using the operation and
programming guidelines described below.
K-2000-DVA Compatibility with
RC-2A and RC-3
B. Configuring the RC-2A/RC-3 for use with the K-2000-DVA
1. The RC-2A or RC-3 security or access code must be enabled.
2. Security and/or access code(s) for RC-2A or RC-3 must differ from those of the K-2000-DVA.
3. The RC-2A or RC-3 should be set for maximum ring delay (15 rings for RC-2A, 31 rings for RC-3).
C. Configuring the K-2000-DVA for use with the RC-2A or RC-3
1. The security and access codes for the K-2000-DVA must differ from those of the RC-2A or RC-3.
2. The K-2000-DVA must be set to answer in fewer rings than the RC-2A/RC-3.
D. Accessing the K-2000-DVA and RC-2A/RC-3
a. While the K-2000-DVA is in “Reporting Mode”
1. Call into the K-2000-DVA and RC-2A/RC-3 combination.
2. When the K-2000-DVA answers, enter Q + the 6 digit access code for the K-2000-DVA. Two beeps will be
heard from the K-2000-DVA and the RC-2A/RC-3 will return either silence or an error tone respectively.
These error tones can be ignored. The K-2000-DVA may now be operated normally.
b. While the K-2000-DVA is in “Polling Mode”
If the K-2000-DVA is in “Polling Mode”, the K-2000-DVA may be operated normally.
2. Accessing the RC-2A or RC-3
While online with the K-2000-DVA, enter Q + the 3 or 6 digit access code for the RC-2A or RC-3 respectively. The
RC-2A/RC-3 may now be operated normally.
Note: The “force hang-up” command will not automatically release
the line, the user must hang-up.
Reporting Mode - The mode of operation in which the K-2000-DVA has been triggered to dial out,
for purposes of making contact with a party.
Polling Mode - The mode of operation in which a calling party has called into the K-2000-DVA for
purposes of retrieving or clearing stored messages.
Important Potential Conflicts - The RC-3 may be programmed while on-line with
the K-2000-DVA. However, due to potential Touch Tone conflicts, programming
of the K-2000-DVA should NOT be attempted while on-line with RC-2A or RC-3.
Programming of the K-2000-DVA via the RS-232 port is unaffected by this conflict
and is the preferred method of programming.
Programming/Operation
Fax Back Doc # 830
A. Definitions
Printed in the U.S.A.
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions of
this document or new editions of it may be issued to incorporate such changes.
Product Support Line...(715) 386-8666 Fax Back Line...(715) 386-4345
RC-3
Fax Back Document 165
RC-2A
Fax Back Document 160
K-2000-DVA
Fax Back Document 303
1. Accessing the K-2000-DVA

Other manuals for Viking K-2000-DVA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viking K-2000-DVA and is the answer not in the manual?

Viking K-2000-DVA Specifications

General IconGeneral
BrandViking
ModelK-2000-DVA
CategoryTelephone Accessories
LanguageEnglish

Related product manuals