INSTALLATION / USE & CARE
|
17
F
reestandin
units usin
natural
as, usin
a metal fl e
hose is recommended.
This is available at your local hardware store or from your
ealer
LP
A
Grills set u
for LP gas come e
ui
ed with an LP hose/
regulator assembly for connection to a standard 20 lb.
LP cylinder. (Ty
e 1). All fi ttings necessary to attach the
assembl
to the
rill are included.
Permanent
y p
um
e
LP connections, suc
as t
ose in
ine
with a bulk cylinder, require a 4/11 regulator
When using the 4/11 regulator you must ensure that it
is set for the
ro
er fuel ty
e. This is done by removing
the regulator ca
and gasket and looking at the bottom
of the plunger to see what fuel type is visible. This is the
regulator fuel setting. NAT is for natural gas and LP is for
ro
ane gas. The LP setting can be further identifi ed by
the large diameter disk on the bottom of the plunger. To
change from one gas to the other sim
ly
ush the
lunge
to the side to snap it out of the cap, turn the plunger so
it reads the desired gas type on the bottom, and push
the plunger until it snaps back into place in the cap then
replace the cap into the regulator
Never connect an unregulated gas line to the grill.
LP Cylinder Requirements
The LP c
linder must be constructed and marked in accor
dance with the s
ecifi cations for LP gas cylinders of the U.S.
Department of Transportation (DOT) and designed for use
wit
a Type 1 system on
y.
C
linders of free standin
rills must be secured usin
the
provi
e
cy
in
er retention system to avoi
acci
enta
movement.
When exchan
in
ou
cylinder for a refi ll,
exchange only for a
Type 1 20
cy
in
er wit
an over-fi ll protection
devi
e.
Never use a c
linder with a dama
ed valve.
A dented or rust
LP c
linder ma
be hazardous and should
be avoided. If in doubt, have it checked by your LP su
lier.
Always check for leaks after every LP cylinder change. (See
INDEX: “Leak Test” for further details.)
Always shut off the LP-gas supply at the cylinder when the
grill is not in use.
Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children. If your grill is stored indoors,
the LP c
linder must be stored outside.
LP Connections
Make sure the LP cylinder valve is fully closed. It is
ossible
for the valve to be o
en without releasing gas but, as soon
as
ou start connectin
the re
ulator,
as will leak from the
onne
tion.
LP cylinder with type 1 valve connection
A
NNE
TI
N
n
in
Do not change the regulator/hose assembly or
use any other assembly than the one supplied
with your grill.
Do not attempt to use a 5LP-A equipped
regulator/hose assembly with a standard 510 POL
cylinder/valve assembly.
Do not store a spare LP-gas cylinder under or
near this appliance.
Never fi ll the cylinder beyond 80 percent full.
If the information above is not followed exactly, a
fi re causing death or serious injury may occur.
WARNING