Do you have a question about the Villa Sistemi Medicali ENDOS AC and is the answer not in the manual?
Category | Medical Equipment |
---|---|
Type | Endoscope Washer Disinfector |
Brand | Villa Sistemi Medicali |
Model | ENDOS AC |
Capacity | 1 endoscope |
Compatibility | Flexible endoscopes |
Power Supply | 220-240V, 50/60Hz |
Disinfection Method | Automated chemical disinfection |
Explains symbols used in the manual for notes and warnings.
Provides crucial safety information and precautions for equipment use.
Details measures for protecting patients and operators from radiation.
Discusses materials and safe disposal of the equipment.
Lists and explains symbols found in the manual and on the device.
Outlines steps for maintaining hygiene and cleaning the equipment.
Shows and describes various labels and their information on the device.
Describes the main components and variations of the ENDOS AC/ACP.
Details the articulated arm system for positioning the tubehead.
Describes the X-ray emitting part of the equipment.
Explains the function and types of timers used (ENDOS ACP/AC).
Presents different ways the equipment can be set up or installed.
Illustrates the typical wall-mounted setup.
Shows the setup with a remote timer unit.
Depicts the setup integrated with a dental chair.
Illustrates the equipment mounted on the ceiling.
Shows the equipment mounted on a mobile stand.
Explains setup options for remote operation.
Lists key technical specifications of the ENDOS AC/ACP equipment.
Provides detailed technical specifications related to the tubehead.
Details specifications for the different X-ray tubes used.
Specifies operating and storage conditions for the equipment.
Lists the weight of the main unit and its components.
Explains the automatic exposure time correction based on line voltage.
Describes how to measure kVp, mA, and exposure time (t).
Discusses accurate measurement of exposure times using dosimeters.
Presents graphical data related to tube emission characteristics.
Lists applicable regulations and standards for the equipment.
Provides dimensional drawings and measurements for different configurations.
Details the operation of the ENDOS ACP digital timer.
Details the operation of the ENDOS AC digital timer.
Explains the meaning of indicator lights and display messages.
Covers the initial setup and configuration of the timer.
Guides on setting up automatic exposure selection for film.
Guides on setting up manual exposure selection.
Guides on setting up automatic selection for digital radiography.
Describes how to position and prepare the tubehead for exposure.
Explains the standard techniques for intraoral radiography.
Details the bisecting angle technique for positioning.
Details the parallel technique for positioning.
Describes the steps involved in performing an X-ray exposure.
Covers advanced features and parameters of the timer.
Explains how to check the total number of exposures.
Guides on adjusting the factor for various film speeds.
Guides on adjusting the factor for digital sensors.
Lists and explains messages indicating the equipment's operational status.
Introduces the system for reporting errors and malfunctions.
Lists errors requiring technical service intervention.
Lists errors that allow partial operation after reset.
Lists errors detected during the exposure process.
Discusses common image artifacts and their causes.
Identifies errors resulting from incorrect patient or tubehead positioning.
Outlines routine checks and maintenance tasks for the operator and technician.