VISOKOTLAČNI ČISTILEC
Villager VHW 155
Originalna navodila za uporabo
PRED UPORABO PREBERITE TA NAVODILA.

Questions and Answers

  • H
    Harry CraigAug 11, 2025
    Why doesn't my Villager VHW 155 Pressure Washer reach the necessary pressure?
    • C
      Catherine HintonAug 11, 2025
      If your Villager Pressure Washer pump isn't reaching the necessary pressure, start by cleaning the water inlet filter and ensuring all supply connections are tight, including checking for leaks in the water feeding hose. Also, inspect the suction/delivery valves for clogs or wear and clear or replace them if needed. You can try loosening and re-tightening the regulation screw. Finally, check the lance nozzle and replace it if it's incorrect or worn out. The cause may be a clogged water inlet filter, air being sucked into the pump from connections or hoses, clogged or worn-out suction/delivery valves, a stuck unloaded valve, or an incorrect/worn-out lance nozzle.
  • C
    Cynthia PonceAug 17, 2025
    What to do if my Villager VHW 155 Pressure Washer motor stops suddenly?
    • A
      alan40Aug 17, 2025
      If your Villager Pressure Washer motor stops suddenly, it might be due to the thermal safety switch tripping because of overheating. To resolve this, ensure the main voltage corresponds to the specifications. Then, switch off the unit and allow it to cool down for a few minutes.
  • J
    Jessica BoydAug 22, 2025
    Why is the pressure fluctuating on my Villager Pressure Washer?
    • T
      Timothy PearsonAug 22, 2025
      If your Villager Pressure Washer exhibits fluctuating pressure, it could be due to the pump sucking air, dirty, worn out or stuck valves, or worn-out pump seals. Ensure that hoses and connections are airtight. Clean and replace the valves, or consult a dealer for assistance.
  • N
    nmasonAug 28, 2025
    How to troubleshoot a Villager Pressure Washer that won't start?
    • L
      lewislauraAug 29, 2025
      If your Villager Pressure Washer won't start when switched on, check the plug and socket to ensure they are well-connected and not faulty. Also, verify that the main voltage is adequate and meets the minimum requirement. If the pump is stuck, refer to the after-storage instructions. Additionally, if the thermal safety switch has tripped, switch off the unit, let the motor cool for a few minutes, and leave the lance open. The cause may be a poorly connected plug, a faulty socket, insufficient main voltage, a stuck pump, or a tripped thermal safety switch.
  • R
    Robert StewartSep 3, 2025
    What to do if my Villager VHW 155 is leaking water from the pump?
    • W
      William MaySep 4, 2025
      If water is leaking from the pump of your Villager Pressure Washer, it's likely due to worn-out seals. Check and replace the seals, or consult a dealer for assistance.

Villager VHW 155 Specifications

General IconGeneral
Max. flow7.5 L/min
Max. water temperature50 °C
Frequency50 Hz
Pump typeAluminum
Maximum Pressure170 bar
Flow Rate15 l/min
Power3 kW
Voltage230 V