Troubleshooting
TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Problem Likely Cause Remedy
Door Gasket not
Door gasket is twisted See section on door gaskets
sealing properly
page 19
Lost its flexibility See section on door gaskets
page 19
Will not start
Thermostat delay Allow enough time for
thermostat start up delay
Tripping circuit breaker Reset breaker, verify dedicated
15-amp outlet and not on GFI
Temperature setting Adjust your set temperature
Wine probe connections Assure probe line is in a bottle of
water and line is not stretched
Runs constantly
Thermostat setting May be set too cool, raise the set
temperature
Cabinet recently loaded May take several weeks to
with wine reach optimal storage temperature
Ambient room temperature Units cool 30 degrees below
ambient, may need to run
Inadequate ventilation Assure proper space above,
behind & on side of unit. Do NOT
stack anything on top!
Door gasket not sealing See section on door gaskets.
properly. page 19
Not cooling
Thermostat setting May be set too warm, lower set
temperature
Thermostat not operating Test unit with by-pass plug
correctly page 19
Low on refrigerant/freon Unit may need service. Contact
Customer Service
Temperature Variation
Temperature Equalizer fan See Temperature Equalizer
page 13
Icing up
Unit running constantly See above information on units
running constantly
Low on refrigerant/freon Unit may need service. Contact
Customer Service
Thermostat Test unit with by-pass plug
page 19
Clicking noise during
Outlet power Assure dedicated 15 amp outlet
startup
and not on a GFI
-18-