20 DE5110
$33(1',;$5(027($1'/2&$/&20387(5&21752/
Total remote and local control of the MAESTRO-1600DL as well
as data download/upload are possible, using optional hardware
and computer software. A separate instruction manual will be
supplied to purchasers of these optional items.
$ 5HPRWH &RQWURO
The optional items offered for remote control and download/upload
operations are listed below and shown in Fig. A.1.
The RM-1000 remote control modem.
An RS-232 cable assembly, terminated with RJ-11 plug at the
modem side, and a 9-pin D-type plug at the computer side.
RPM-1 (Remote Programming Manager #1) software package
that runs on IBM-PC™ and compatibles under Microsoft
Windows™.
This equipment and software, together with the remote
computer, permit the remote station operator to:
Exercise full remote control of the MAESTRO-1600DL, including
status and data retrieval.
Prepare and save new memory maps for the
MAESTRO-1600DL. The data can then be downloaded via the
telephone line into the system's memory.
Upload the current memory map of any MAESTRO-1600DL.
The data can then be changed, saved and downloaded back
into the same MAESTRO-1600DL.
$ /RFDO &RQWURO
Local control requires the same equipment as remote control, plus
a local control cable assembly (supplied in the remote control kit)to
be connected between the local control headers of the RM-1000
and the MAESTRO-1600 alarm control module (Fig. A.1).
Figure A-1. Remote and Local Control Configurations
Local control permits the operator to carry out the same operations
possible from a remote station, as listed in Para. A.1 above. The
only difference is that data interchange is effected via the local
control cable and not via the telephone line.