vitapur VUV-S375B - Product Overview; Components Identification

vitapur VUV-S375B
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product overvIew:
The Vitapur
®
Ultraviolet (UV) Water Treatment System has been engineered to rigid standards, and
has been quality inspected at the factory prior to packaging. Please review this manual in its entirety
for a detailed system explanation, and ensure that the following components accompany this
system: To ensure system performance, all replacement components should be purchased directly
from an authorized dealer or directly from GHP Group Inc. (www.ghpgroupinc.com). The use of
components purchased from other sources will void the warranty, and will potentially cause the
system to function in a lesser capacity than intended.
• Do not attempt to service this unit unless you are an accredited service technician, as personal
injury could result and/or system operation could be detrimentally affected.
• Never operate this unit in an oxygen-rich environment, or within 6 feet (2 meters) of any oxygen
source.
• If temperatures should fall below freezing (0°C / 32°F), drain all water from the unit, drain and
disconnect all plumbing lines, and cap the inlet and outlet ports.
!
Power
(green)
Lamp Failure (red)
!
Power (green)
Lamp Failure
(red)
!
Power
(green)
Lamp Failure
(red)
Owners Manual
Electronic Ballast
(Includes lamp connector)
UV Lamp
Quartz Sleeve
Stainless Steel UV Reaction Chamber
Power Cord
VuCap
®
UV Cylinder
Mounting
Clamps and
screws
Retaining Nut
Quartz Sleeve
Sealing O-Ring
Hardware Kit
(2 screws, 2 anchors)
!
Power (green)
Lamp Failure (red)
CAUTION: Before using UV System, read this manual and follow all safety rules and operating instructions.
Installation Instructions & Owner’s Manual
Ultraviolet (UV) Water Treatment System
MODEL: VUV-S375B, VUV-S645B, VUV-H375B, VUV-H645B
System tested and certied by NSF
International against NSF/ANSI
Standard 55 and CSA B483.1 for
disinfection performance
181213
x2
Flow Restrictor
A minimum 5 µ nominal pre-lter is recommended upstream (before) the UV system installation
point. As UV system efciencies are dictated by penetration of the UV light through the water
column, particulate matter within the water column could decrease the disinfection capacity, and
potentially create a harmful condition (ltration systems sold separately).
• Lamps must be replaced after 12 months of operation to ensure
proper disinfection of your water
• Clean Quartz Sleeve frequently for optimum performance