Trouble shooting
20
Compressor
The inlet and outlet valve of the compressor is damaged,
making the low pressure connected with the high pressure.
The refrigerating system can not produce high pressure
and low pressure. Replace the compressor after checking
for the reason.
Heat sources Reduce if too many.
No power Check the voltage. Call an electrician if no within the limit.
Wiring Check the terminals. Repair and correct if loose.
Temperature setting Check and adjust the temperature setting.
Mode setting Check and adjust the mode setting.
Compressor
Check and replace if the compressor, the over-load
protector or wiring is broken.
Electric heater failure Check and replace if the heater is damaged.
Over heat fuse failure Check and replace if the fuse is damaged.
No cooling or
heating.
Main PCB
Check the voltage of main PCB. Replace the main PCB
when the unit failure in heating mode.
Power supply
The input power supply voltage is too low. Call an
electrician if not within limits.
Main PCB
Check and replace the main PCB if the compressor relay
on PCB is shorted or damaged.
The unit starts
and stops
frequently.
Room temperature
When the room temperature is too high, the compressor
will protect.