1615
Take out the batteries in case of a long period of no-use.
If the tool does not work, please inspect whether the batteries are in
a stable connection or the voltage is below an acceptable operating
level. If not, please inspect whether the tip is dirty and in a stable
connection with the probe.
Your part in opening the tool is beyond the warranty service.
●
●
●
Applications
Detect leaks in other systems and storage/recovery containers. It will
respond to All halogenated (contains Chlorine of Fluorine) refriger-
ants. This includes, but is not limited to:
CFCs, e.g., R12, R11, R500, R503, etc.
HCFCs, e.g., R22, R123, R124, R502, etc.
HFCs, e.g., R134a,R404a, R125, etc.
Blends such as AZ-50, HP62, MP39, etc.
Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it
will detect the halogenated carrier gas).
Detect SF-6 in high-voltage circuit breakers.
Detect most gases that contain chlorine, Fluorine and Bromine(halo-
gen gases).
Detect cleaning agents used in dry cleaning applications such as
perchloroethy.
Detects halogen gases in a fire-extinguishing system.
●
●
●
●
●
Maintenance
Keep the sensing tip clean from dust, moisture, and grease.
If the tip itself is dirty it can be cleaned by immersing in a mild
solvent, such as alcohol, for several seconds, and then using com-
pressed air and/or a towel to clean. Never use solvents such as gaso-
line, turpentine, minerals etc. for they will leave detectable residue
and desensitize your unit.
Warning: Turn the tool off before repacing the sensing tip. Failure to
do so may result in a mild electrical shock!
Sensing tip repacement: the tip will eventually wear out and require
repacement. It is difficult to predict exactly when this will occur
since tip longevity is directly reated to the conditions and frequency
of use. The tip should be repaced whenever the aarm sounds or
becomes erratic in a clean and pure environment.
Appropriate maintenance of your leak detector is very important.
Carefully following the instructions to reduce the mal-operation and
prolong the life expectancy of the unit.
●
●
●
Specifications and Parameter
Operating temperature: 0°Cto 52°C (30°F to 125°F)
Maximum sensitivity: 6 gr/yr, for all halogenated refrigerants.
Battery life: Approximately 50 hours normal use.
Response time: Instantaneous.
Work mode: Continuous, no limitation.
Fixed Probe Length: 20cm.
Unit Dimensions: 22.9cm x 6.5cm x 6.5cm.
Warm-up time: Approximately 6 seconds.
Reset Time: Two to ten second.
Power Supply: 6V DC four cell 7# excellent batteries.
●
●
●
●
●
●
●
●
●
●