7
bit correctly, and then you are able to send the below commands in command sending
area.
Command and
Feedback Example
Set the RELAY 1 working time to [xxx].
xxx=0~655s.
After sending the command, the Relay 1 port will perform
the below actions:
1) The NO connection closes, and NC connection opens.
2) When the working time is up, the NO connection
opens, and NC connection closes.
Set the relay1 to work
for 10 seconds!
Set the RELAY 2 working time to [xxx].
xxx=0~655s.
After sending the command, the Relay 2 port will perform
the below actions:
1) The NO connection closes, and NC connection opens.
2) When the working time is up, the NO connection
opens, and NC connection closes.
Set the relay2 to work
for 10 seconds!
Immediately stop the work process of relay 1.
Immediately stop the work process of relay 2.
Relay 1 closes for one second, and then opens.
Set the relay1 to work
for 1 seconds!
Relay 2 closes for one second, and then opens.
Set the relay2 to work
for 1 seconds!
Note: When using RS232 pass-through to control the third-party device, the beginning
and end of control commands must be respectively added “@” and “@+”. The format
is: “@........@+”.