EasyManua.ls Logo

VivoLink VLHDMIEXT416 - Page 7

Default Icon
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
bit correctly, and then you are able to send the below commands in command sending
area.
Description
Command and
Feedback Example
Set the RELAY 1 working time to [xxx].
xxx=0~655s.
After sending the command, the Relay 1 port will perform
the below actions:
1) The NO connection closes, and NC connection opens.
2) When the working time is up, the NO connection
opens, and NC connection closes.
Relay1Wot:10.
Set the relay1 to work
for 10 seconds!
1
2
3
4
8
9
10
Set the RELAY 2 working time to [xxx].
xxx=0~655s.
After sending the command, the Relay 2 port will perform
the below actions:
1) The NO connection closes, and NC connection opens.
2) When the working time is up, the NO connection
opens, and NC connection closes.
Relay2Wot:10.
Set the relay2 to work
for 10 seconds!
1
2
3
4
8
9
10
Immediately stop the work process of relay 1.
Stop relay1 operation!
Immediately stop the work process of relay 2.
Stop relay2 operation!
Relay 1 closes for one second, and then opens.
Set the relay1 to work
for 1 seconds!
Instruction completion
Relay 2 closes for one second, and then opens.
Set the relay2 to work
for 1 seconds!
Instruction completion
Relay 1 remains closed.
Keep relay 1 closed
Relay 2 remains closed.
Keep relay 2 closed
Note: When using RS232 pass-through to control the third-party device, the beginning
and end of control commands must be respectively added “@” and “@+”. The format
is: “@........@+.