<product dependent> outdoor,- "outdoor": Auto-setting P-Iris to get best
quality, but easy to meet rolling or flicker effect
in indoor environment.
"indoor": Avoid rolling and flicker effect first.
"manual": Manual set P-Iris by
"piris_position".
"-": not support (only available when
"capability_image_c<0~(n-1)>_sensortype"
is "smartsensor")
* Only available when
"capability_image_c<n>_iristype"=piris
piris_position
<product dependent>
1~100 1/4 Manual set P-Iris.
1: Open <-> 100: Close
* Only valid when "piris_mode"=manual or
"capability_image_c<0~(n-1)>_sensortype"
is "smartsensor"
* Only available when
"capability_image_c<n>_iristype"=piris
irismode fixed, indoor,
outdoor
<product
dependent>
4/4 Control DC-Iris mode.
"outdoor": Auto-setting DC-Iris to get best
quality, but easy to meet rolling or flicker effect
in indoor environment.
"indoor": Avoid rolling and flicker effect first.
"fixed": Open the iris to maximum.
* Only available when
"capability_image_c<n>_iristype"=dciris
wdrpro_mode
<product dependent>
<boolean> 4/4 Enable WDR pro
* Only available when
"capability_image_c<n>_wdrpro_mode" > 0
wdrpro_strength
<product dependent>
1~100 4/4 The strength of WDR Pro.
The bigger value means the stronger strength
of WDR Pro.
* Only available when
"capability_image_c<n>_wdrpro_strength" is
1
wdrc_mode
<product dependent>
<boolean> 4/4 Enable WDR enhanced.
* Only available when
"capability_image_c<n>_wdrc_mode" is 1