wdrpro_description <string> 0/7 Description about WDR Pro mode.
* Only available when
"capability_image_c<0~(n-1)>_wdrp
ro_mode" > 0
wdrc_mode 0, 1 0/7 0: Non-support WDR Enhanced
1: Support WDR Enhanced
wdrc_supportlevel 0, <positive integer> 0/7 Indicate the support strength level of
WDR Enhanced.
wdrc_affect -,
exposurewin.mode:fixed:au
to,
exposurewin.mode.blc:disab
led:,
aespeed:disabled:,
exposurelevel:hidden:,
exposurelevel:fixed:<x>,
exposurelevel:ranged:<x>-
<x>,
exposuremode:fixed:auto
<x>: nonnegative integer
<product dependent>
0/7 When WDR Pro or WDR Enhanced is
enabled, some features may become
malfunction or be forced to a given
value. The affected functions are list
here.
The format is "Affect API
name":"Policy":"Value"
"Policy" can be categorized into
following groups:
- (disabled) : UI turns grey and users
can't select it.
- (unchanged) : UI keeps the status as
before and user can't change it.
- (hidden) : UI is hidden.
- (fixed) : UI is fixed to one selection or
value.
- (ranged) : UI is fixed to multiple
selections or values.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word as
well, such as "exposurelevel:fixed:6"
which means exposurelevel is fixed to
level 6.
"Value" can be a nonnegative integer
or NULL.