Group: event_i<0~2>
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
name string[40] NULL 6/6 Identification of this entry.
enable 0, 1 0 6/6 Enable or disable this event.
priority 0, 1, 2 1 6/6 Indicate the priority of this event:
“0” = low priority
“1” = normal priority
“2” = high priority
delay 1~999 10 6/6 Delay in seconds before detecting
the next event.
trigger boot,
di,
motion,
seq,
recnotify,
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording
notification.
triggerstatus String[40] triggerstatus 6/6 The status for event trigger
di <integer> 1 6/6 Indicate which DI detects.
This field is required when trigger
condition is “di”.
One bit represents one digital
input. The LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate which motion detection
windows detect.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and
3
rd
windows, set mdwin as 5.
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.