Extended Systems
- The fresh-air/air-recirculation flap is
combined with the back pressure flap.
- Fresh-air blower with integrated
control unit.
- The shape of the central flap has been
modified to allow separate airflow to
the central and side vents.
- All flaps are electic-motor-operated.
Air-conditioning without back pressure flap is installed
in right-hand drive vehicles.
The following components are integrated in
the refrigeration circuit:
- Plate evaporator
- Controlled swash plate compressor
- Condenser
- Butterfly valve
- Collecting vessel
The Air-conditioning
Central flap
Fresh-air blower
Back pressure flapFresh-air/air-recirculation flap
191/42