EXECUTE MODE VOLTECH AT3600 USER MANUAL
3.1. EXECUTE MODE WITH NO OPTIONS ENABLED
For simple test programs (where none of the following options are enabled: Batch
Number, Operator Number or Serial Number), the following flow diagram
summarises EXECUTE MODE operation:
Enter Program
Name or Select
from a List
Fixture
Compensation
NO
COMP
Top-level
Display
Select
EXECUTE Mode
Fit the
fixture
Compensate
Fixture?
COMPENSATE
At the top-level display, press EXECUTE.
The program name can now be typed at the keyboard, entered
by swiping a barcode or chosen from a list. Press the soft-key
LIST to see a list of the programs available on the PC server or
in the AT3600’s own memory (see section 6.6.2)
Use the and keys to select the program and press the enter
key [ ] or the enter soft-key.
UNIVERSAL is the name given as the ‘Fixture ID’ in the
Editor software ‘Program options’ dialogue (see Chapter 3).
Press COMPENSATE or NO COMP as required.
Note: For fixture compensation, connect a short circuit in
place of each winding of the transformer under test.