Boom Hose Rupture Valve Operation
P3 port is connected to overload pressure switch(A).
With Pi signal,boom lowering is possible.
The spool movement makes the tank connection of pilot check valve.
Picture text: 1 : Neutral condition
2 : Raising operation
3 : Lowering operation