Auto-return to idle
Without any movement of machine, engine speed automatically goes down to I1 mode. This increase fuel
economy and decrease noise. After engine has decelerated, if the operator changes one of input signals,
then engine speed return to the previous speed.
Default time delay is 5 second. This can be adjusted form 3 to 10 seconds by VCADS Pro.