Tank Electrode 12-24 K Tank Height 12 - 24 cm, 12 V and 24 V Order-No. 5543
Tank Electrode 15-50 K
Tank Height 15 - 50 cm, 12 V and 24 V Order-No. 5545
According to Drinking Water Ordinance DIN 2001-2
The tank transmitter had been designed for precise level measuring of fresh water tanks, sewage water tanks
and feces tanks of plastic and metal material in campers, caravans and boats.
Measurement of the level is effected fully-automatically without mechanically moving parts according to the
capacitive method of measurement, and it is transferred to the display unit via a three-core cable.
The electronic system is completely sealed. Thus, it is extremely robust and insensitive to soiling.
Tank measuring sensor, suitable and required for VOTRONIC tank displays, 1 piece per tank:
Tank Display Units: Order No. 12 V Order No. 24 V
• Fresh Water Tank Display S 5311 5311
• Sewage Water Tank Display S 5313 5313
• Feces Tank Display S 5315 5315
• Info Panel Pro 5330 6330
• Votronic VBS 2 Bus System All Types All Types
• Votronic VPC System All Types All Types
• Previous Votronic tank displays since 1987 All Types All Types
For remote level measurement, the tank electrode
is installed directly at the tank. It is suitable for:
• Fresh water (if applicable, please observe the
Guidelines for Drinking-Water Quality DIN
2001-2)
• Sewage water, grey water
• Feces sewage water
• Plastic tanks, any material
• Metal tanks (aluminium, steel, stainless steel,
etc.)
• Adjustable to tank heights:
12 to 24 cm or 15 cm to 50 cm.
Functioning:
The level in the tank is measured capacitively. The
insulated stick (probe) and the surrounding water
form a kind of "capacitor", the size of which is
growing with the level, and which is measured by
the electronic system. The contact to the water as
"antipole" is effected by a stainless steel stick.
Brief Instruction:
1.
Produce a mounting hole at the tank with a diameter of 38 mm or thread PG29.
2. Determine the kind of installation, inside or outside the tank, and measure the tank height.
3. Cut both measuring sticks to the desired length (observe a clearance of 10 - 20 mm between sticks and tank
bottom).
4. Reinsert the insulating cap on the insulated stick (observe the tightness).
5. Install the tank transmitter inside or outside using the delivered packing ring.
6. Set the measured water depth at the scale.
7. Produce the electrical connection to the display unit.
8. Ready for start-up.