EasyManua.ls Logo

Vyaire bellavista 1000 - User Manual

Vyaire bellavista 1000
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Set Up and Start Up Guide
bellavista
TM
1000 and bellavista
TM
1000e
Question and Answer IconNeed help?

Do you have a question about the Vyaire bellavista 1000 and is the answer not in the manual?

Summary

Dual Limb Circuit Setup

Gather Circuit Components

Lists necessary components for active and passive humidification circuits.

Exhalation Valve Procedures

Details selecting and attaching single-use or reusable exhalation valves.

Connect Circuitry and Filters

Covers connecting humidification and filters to the inspiratory and expiratory limbs.

Connect iflow Sensor and Tubing

Details connecting the iflow sensor and tubing to the ventilator circuit.

Power Up and Connection Assist

Describes powering on the device and accessing the Connection Assist feature.

Initial Ventilator Configuration

Start Screen and Patient Setup

Guides through the start screen, patient selection, and profile setup.

Circuit Type Selection

Guides through selecting Invasive, Non-Invasive, or HFOT circuit types.

Automatic Tube Compensation (ATC)

Explains how to enable and configure Automatic Tube Compensation (ATC).

Performing the Circuit Test

Details the steps for performing and verifying the circuit test.

Ventilator Operation and Modes

Cockpit Screen Overview

Introduces the customizable Cockpit screen for monitoring waveforms and settings.

Expert Ventilation Modes

Describes Manoeuvres, Settings Assist, and Backup Settings screens.

Animated Lung Visualization

Explains the use of the Animated Lung feature for visual patient status assessment.

Alarm Settings and Management

Covers setting and managing alarms, and accessing functions like O2 Suction.

Special Ventilation Modes (NIV, HFOT)

Guides on configuring Non-Invasive (NIV) and High Flow Oxygen Therapy (HFOT) modes.

Target Vent (PRVC) Mode

Details the process for activating and configuring the Target Vent (PRVC) mode.

System Management and Maintenance

Stopping Ventilation and Screen Lock

Procedures for stopping ventilation, locking, and unlocking the screen.

Accessing the User Manual

Instructions on how to access the built-in user manual via Help.

O2 Sensor Calibration and Management

Steps for calibrating, managing, and disabling the oxygen sensor.

HEPA and Cooling Filter Maintenance

Guidance on maintaining HEPA and cooling filters, including replacement intervals.

Vyaire bellavista 1000 Specifications

General IconGeneral
TypeVentilator
ModelBellavista 1000
ManufacturerVyaire Medical
Patient TypesAdult, Pediatric, Neonatal
Tidal Volume Range20-2000 ml
FiO2 Range21-100%
Peak FlowUp to 180 L/min
Power SourceAC power, Battery
Battery BackupYes
Ventilation ModesVolume Control, Pressure Control, SIMV, CPAP
Inspiratory Time0.1-5 seconds
O2 Supply Pressure50 psi
Heated HumidifierIntegrated, optional
ConnectivityEthernet, USB
Respiratory Rate1-150 breaths/min

Related product manuals